Products
The Bun Flood with its external sensor cable, an alarm goes off when it detects that the area is getting wet It is ideal during joints on lengths of pipe or areas that are important to be dry. The cable is available in different lengths so that you can cover your area as best as possible.
Loggerflex Bun Flood water leakage detector w. sensor cable
EAN 5706445877034
EL-NR 6398877033
In stock Few in stock Not in stock
202.00 EUR Ex. VAT
Extremely simple operation when using the milliohm principle. Simple rotary switch for selection of standard cable dimensions from 0.15 to 240 square and push button for selection of aluminum or copper. In addition, 8 user-definable cable types. The Kelvin measuring principle automatically calibrates the resistance of the test leads and clamps, which, together with temperature compensation, ensures accurate results.
Elma 6501 is both a cable length meter and miliohmmeter, with a resolution down to 100µΩ, and can therefore also be used for measuring small resistances.
Measurement of cable lengths based on resistance, in contrast to cable length meters based on TDR reflectometer technology, does not depend on known NVP value (signal speed), which can often be unknown on installation cables. Just set the rotary switch to the cable dimension, join/short two conductors and connect clamps to the de-energized cable and read the result. The length is simply calculated on the basis of the measured resistance, which is predefined for standard cable dimensions. No complicated settings, just a simple reading.
The Elma 6501 cable length meter and milliohm meter is ready to use with 4-wire alligator clips test leads, batteries and manual.
Elma 6501 Cable Length Tester
EAN 5706445840717
EL-NR 6398215080
In stock Few in stock Not in stock
238.00 EUR Ex. VAT
Elma 641, leakage detection on pressurerized air
EAN 5706445640010
EL-NR 6398955641
In stock Few in stock Not in stock
404.00 EUR Ex. VAT
Elma Easy flex SPECIAL KIT - strong case and headset 641
EAN 5706445640324
EL-NR 6398955612
In stock Few in stock Not in stock
754.00 EUR Ex. VAT
Elma 44 TDR meter
EAN 5706445660018
EL-NR 6398942340
In stock Few in stock Not in stock
828.00 EUR Ex. VAT
Elma 4000/D37N is the ideal kit to identify fails to ground in IT and TT nets and leak current in IT, TN and TT nets. The set consist of a 4Hz transmitter and a receiver with a current clamp to pick up the signal and read out the fail to ground or leakage current. Using the transmitter to detect (IT net): The generator is inserted between any phase and ground. The current clamp is connected to the digital receiver and the fault to ground is read out as a percentage (%) of the full generator loop power. The Generator is supplied with 230V and a LED will flash with the signal frequency. Using only the clamp (All nets): The current clamp is connected to the receiver and the leakage current is read directly as mA. The selector is set at 50Hz A/mA and the clamp should enclose all wires including the neutral. Elma 4000/D37N is delivered ready to use in a suitcase with Generator, reciever and current clamp type D37N Ø156x66mm.
Elma 4000/D37N Leak current locator
EAN 7090009210190
EL-NR 6398401179
In stock Few in stock Not in stock
1,978.00 EUR Ex. VAT
Elma 4000/D37N is the ideal kit to identify fails to ground in IT and TT nets and leak current in IT, TN and TT nets. The set consist of a 4Hz transmitter and a receiver with a current clamp to pick up the signal and read out the fail to ground or leakage current. Using the transmitter to detect (IT net): The generator is inserted between any phase and ground. The current clamp is connected to the digital receiver and the fault to ground is read out as a percentage (%) of the full generator loop power. The Generator is supplied with 230V and a LED will flash with the signal frequency. Using only the clamp (All nets): The current clamp is connected to the receiver and the leakage current is read directly as mA. The selector is set at 50Hz A/mA and the clamp should enclose all wires including the neutral. Elma 4000/C173 is delivered ready to use in a suitcase with Generator, reciever and current clamp type C173 Ø54mm.
Elma 4000/C173 Leak current locator
EAN 7090009210183
EL-NR 6398401111
In stock Few in stock Not in stock
1,992.00 EUR Ex. VAT
Elma 4000/D37N is the ideal kit to identify fails to ground in IT and TT nets and leak current in IT, TN and TT nets. The set consist of a 4Hz transmitter and a receiver with a current clamp to pick up the signal and read out the fail to ground or leakage current. Using the transmitter to detect (IT net): The generator is inserted between any phase and ground. The current clamp is connected to the digital receiver and the fault to ground is read out as a percentage (%) of the full generator loop power. The Generator is supplied with 230V and a LED will flash with the signal frequency. Using only the clamp (All nets): The current clamp is connected to the receiver and the leakage current is read directly as mA. The selector is set at 50Hz A/mA and the clamp should enclose all wires including the neutral. Elma 4000/B102 is delivered ready to use in a suitcase with Generator, reciever and current clamp type B102 Ø112mm.
Elma 4000/B102 Leak current locator
EAN 5706445110988
EL-NR 6398401014
In stock Few in stock Not in stock
2,557.00 EUR Ex. VAT
Soundproof headphones
EAN 5706445640157
EL-NR 6398955777
In stock Few in stock Not in stock
202.00 EUR Ex. VAT